Module 7 of 9 · A5 · Monitoring and reporting at an aluminium installation
6.From PFCs to CO2e, and fugitive emissions
- CO2e = CF4 × 6 630 + C2F6 × 11 100.
- Fugitive emissions: total = PFCs measured in the duct ÷ collection efficiency.
- Recommended: own factors from field measurements at least every three years (or after process changes), with uncertainty within ±15 %.
Sources: MA Annex II B.7 Equation 20 p.45, B.7.1 p.46, B.7.3 Equation 26, G Table 6 p.64; G5e §3.1.2 p.22, Table 4-2 p.27; CT-AL sheet B_EmInst.