Module 7 of 9 · A5 · Monitoring and reporting at an aluminium installation
5.PFCs: Method B, overvoltage method
Use this if you record the anode effect overvoltage (AEO) in mV:
- CF4 (t) = OVC × (AEO ÷ current efficiency %) × primary aluminium (t) × 0,001
- C2F6 (t) = CF4 × F_C2F6
Default factors: CWPB 1,16 and 0,121; SWPB 3,65 and 0,252. Both methods are equally valid; pick the one that fits your pot-line control system.
Sources: MA Annex II B.7.2 Equations 24-25, Table 3 p.47; G5e §3.1.2 p.20-22, Table 3-2.