Module 9 of 9 · A6 · Worked example and the communication template

2.Step 1: direct emissions of the installation

Source Calculation t CO2e
Electrodes 69 000 × 3,664 252 816
Natural gas, process 1 12 219 × 48 GJ/t × 56,1 t/TJ ÷ 1 000 32 902
PFCs Method A, see A5 25 282
Process 1 total 311 000
Natural gas, process 2 1 962 × 48 × 56,1 ÷ 1 000 5 283
Installation total 316 283

In the template these go into sheet B_EmInst: section (a) for fuels and anodes, section (b) for PFCs. Sheet C_Emissions&Energy shows the installation total (316 285 t, because the template keeps unrounded figures).

Sources: G5e §4 Table 4-2 p.27; MA Annex II B.3, B.7; CT-AL sheets B_EmInst, C_Emissions&Energy.